Texture image
Thorx main

LUCY ThorX LUCY™ ThorX

SBRT End-to-End QA+ Phantom

LUCY™ ThorX part of complete solution for: Stereotactic

LUCY™ ThorX Overview

Comprehensive Evaluation

  • Entire radiotherapy process for Simulation, Treatment Planning, Imaging, and Delivery, including TG-53, TG-66, and TG-142.
  • 4 primary modules that are assembled using rods, of a density similar to trabecular bone, around the periphery. Various internal structures and test objects as well as external engravings and fiducials are utilized for integrated testing.
  • Pseudo-Anthropomorphic Anatomy
  • Dose Verification: Measure dose with ion chambers and film. Four detector cavities for targets and for Multiple Met SBRT QA.

SBRT Target Pseudo-Anthropomorphic Anatomy

  • Ribs
  • Vertebrae
  • Spinal Cord
  • Lung
  • Kidney

SBRT Dosimetry

  • Rotating Lung Film Rod Insert
  • Spinal Cord Film Insert
  • Multiple Ion Chamber Cavities
  • NanoDot Insert

CT/SIM QA

  • Laser Alignment & Orientation for gantry, walls, ceiling
  • CT Couch Orientation, indexing, motion, and position
  • Slice Thickness / Profile Width & Sensitivity Profile
  • CT Number Constancy
  • Field Uniformity & Image Noise
  • Spatial & Contrast Resolution
  • Virtual SIM with Hidden Target Localization, Contouring, & Laser Movement Accuracy

Treatment Planning QA

  • High-Contrast Kidney Target
  • High-Contrast Triangle Target
  • DICOM Transfer (Scan vs. Export Orientation, Position, Flip, etc.)
  • Spatial & Contrast Resolution
  • Slice Thickness
  • Field Uniformity & Noise
  • CT Number Constancy
  • In-Plane Spatial Integrity
  • Contouring, Margin Creation, DRR Spatial, Dose and DVH Accuracy

Linac Imaging QA

  • DICOM and Volume Transfer Accuracy
  • Spatial Integrity Accuracy
  • TG-142 Position/Reposition, Monthly
  • MV/kV Coordinate Coincidence
  • CBCT Distortion, Spatial Resolution, Contrast, Constancy, Uniformity, and Noise

Treatment Delivery QA

  • High-Contrast Kidney Target with Ion Chamber Measurement in Target and Margin
  • High-Contrast Triangle Target with Ion Chamber Measurement
  • Rotating Insert with Target bisected by Film Plane and Ion Chamber Measurement
  • Spinal Insert bisected by Film Plane
  • Target Localization Delivery Accuracy and Dose Verification

Videos

Webinars

    Register
    Webinar 051624

    May 16th, 2024 / Simplify SBRT and Imaging QA: LUCY ThorX Phantom

    Discover how to revolutionize SBRT QA — from simulation to delivery — with unmatched versatility and realistic evaluation capabilities. LUCY ThorX is an all-in-one solution that simplifies simulation, planning, imaging, and delivery QA, saving you time while ensuring compliance with industry standards. Join us to learn how to streamline your QA routine and meet IAEA TRS 430, TECDOC-1583, TG-53, TG-66, TG-142, and MPPG guidelines.
    Register

Tech Notes

Please sign in or register to the customer care portal to view tech notes.

Have Questions About the LUCY™ ThorX?

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Request Pricing for Complete Stereotactic Solution

Uncompromising tolerances for unwavering trust. Receive more information about Stereotactic QA Solutions.

Learn more about Standard Imaging Stereotactic

Join our Mailing List