Diode Type

  • P-type Si diode, unshielded

Materials

  • C552 shell for EMI shielding and durability, potted with near-water equivalent epoxy to eliminate air gaps

Outside Diameter

  • D1V (REF 92740): Ø 6.88 mm (0.271”) x 46.2 mm (1.817”) long, D1H (REF 92741): 6.88 mm (0.271”) x 6.88 mm (0.271”) x 34.8 mm (1.37”)

Diameter of Sensitive Area

  • 1 mm2 x ~0.05 mm thick

Effective Depth Below Surface

  • 0.8 mm - Indicator marks or lines clearly identify internal diode orientation and active face

Intended Energy Range

  • Photons: 60Co to 25 MV

Low-Noise Triaxial Cable

  • 50 ohms, 29 pF/ft, 1.5 m long

Connector availability

  • Standard BNC triax, with HV bias capability disabled. Other connector options such as TNC or type M may be available upon request.

Waterproof

  • Yes, may be used in water phantoms, designed to mount cleanly and easily to available chamber holders.

Operating Voltage

  • 0 VDC bias (protected from accidental high voltage application)

Signal Polarity

  • Positive

Radiation response, typ

  • ~5 nC/Gy

Leakage current, typ

  • <100 fA (typical, depends on electrometer used)

Temperature dependence, typ

  • <0.4 % / °C

Sensitivity decrease (at 6 MV)

  • <1.0 % per kGy

Dose to pulse dependency

  • > 99.5% over relevant clinical range

Dose linearity

  • > 99.9%

Field size dependency

  • > 97.0%

Intended Field size for use

  • up to (20 x 20) cm2

Directional Dependence

  • < ± 0.5% tilting ± 20

Operating Parameters

  • Temperature: 15 to 35 °C

Relative Humidity

  • 20 to 80% non-condensing

Pressure

  • 650 to 770 mmHg

Temperature

  • -15 to 50 °C

Relative Humidity

  • 10 to 95% non-condensing

Pressure

  • 600 to 800 mmHg

Product Standards Compliance

  • IEC 60601-11, IEC 607311, WEEE, RoHS

Videos

Webinars

    Register

    Jun 1st, 2023 / Truly Water Equivalent Detectors

    Exradin Scintillators are ideal for commissioning SRS and SBRT. Invisible to the beam and providing measurement resolution down to 1x1mm, these detectors are exactly what you need to have confidence in your small field commissioning.
    Register
    Register

    Mar 9th, 2023 / Tools for Scanning Small Fields

    Small fields have met their match. The Exradin Scintillators ensure the tightest treatment margins are delivered safely to patients. Discover the advantages of using these detectors that are invisible to the beam and water equivalent.
    Register

Tech Notes

Please sign in or register to the customer care portal to view tech notes.

Have Questions About the Exradin® D1H Diode Detector?

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Request Pricing for Complete Annual QA Solution

Confidence with fewer gray hairs. Receive more information about Annual QA Solutions.

Learn more about Standard Imaging Annual QA

Join our Mailing List