Texture image
Lucy main 1400

Machine QA

LUCY 3D QA Phantom Unrivaled 0.1 mm accuracy minimizes errors at each link in the stereotactic QA chain.

The Lucy 3D QA Phantom exceeds strict demands set by physicists performing SRS/SRT QA. Each component of the Lucy phantom is manufactured within 0.1 mm tolerances, ensuring the most precise, practical SRS tool on the market.

LUCY™ 3D QA Phantom part of complete solution for: Stereotactic

LUCY™ 3D QA Phantom Overview

Confident Image Fusion

  • Verify the accuracy of image fusion with a single phantom.
  • Fused images can be compared to measurements described in the Lucy specifications to ensure sub-millimeter precision.

Minimize Transfer Errors

  • Industry-leading manufacturing tolerances provide incomparable accuracy when contrasting the Lucy volumes, geometry and distance measurements to images in treatment planning software.
  • These measurements should be evaluated at each step of the imaging process.
  • Rigid tolerances can drastically reduce cumulative uncertainty.

Simple Patient Dosimetry

  • Dosimetry inserts quickly obtain absolute, relative and point-dose dosimetry measurements at isocenter and at exact positions off isocenter.
  • Seamless evaluation of dose as well as geometric accuracy, including CBCT and MV/kV alignment.

Product Dimensions

  • Acrylic Sphere
    140 mm (5.51 in) diameter
  • Blank Filler Plug (HEMI-C)
    81 x 81 x 35 mm (3.19 x 3.19 x 1.38 in)
  • Blank Filler Plug (HEMI-A)
    85 x 85 x 10 mm (3.35 x 3.35 x .39 in)
  • Lucy Midchamber Plug with 4mm Brass Ball
    85 x 85 x 10 mm (3.35 x 3.35 x .39 in)
  • Accessory Port for Ionization Chambers
    8 mm (.31 in) diameter

Videos

Webinars

    Register
    Download

    Jul 30th, 2024 / Development and Evaluation of E2E QA for Single-Isocenter Linac-Based SRS

    Dott. Valeria Faccenda, Medical Physicist at Fondazione IRCCS San Gerardo dei Tintori Monza discusses the clinical development, evaluation and clinical application of an end-to-end test for intracranial stereotactic radiosurgery. Using the Lucy Phantom, they check the accuracy of every step of the treatment chain from simulation CT and MRI fusion, to treatment planning and delivery. Webinar in partnership with Tecnosan.
    Register
    Register

    Jun 22nd, 2023 / End-to-End SRS Verification

    Easily scan, plan, and treat using Lucy 3D QA Phantom. With unrivaled 0.1mm accuracy, it minimizes errors and is the most precise, practical SRS tool on the market. Join us to learn more about the centerpiece of end-to-end SRS QA.
    Register
    Register

    Mar 23rd, 2023 / Complete SRS QA

    When precision and accuracy matter most, use tools that help you achieve that. The LUCY 3D QA Phantom has an unrivaled 0.1mm accuracy when scanning, planning, treating, and verifying. Our patient dosimetry software Adaptivo and LinacView help to monitor treatments and optimize your delivery QA. Discover our complete integrated solutions for complete SRS QA.
    Register
    Register
    Lucy pointer

    Nov 10th, 2022 / End-to-End SRS Verification

    Easily scan, plan, and treat using Lucy 3D QA Phantom. Unrivaled 0.1mm accuracy, it minimizes errors and is the most precise, practical SRS tool on the market. Join us to learn more about the centerpiece of end-to-end SRS QA.
    Register
    Register
    Lucy lockplate

    Jun 2nd, 2022 / End-to-End SRS Verification

    When precision and accuracy matter most – use the Lucy 3D QA Phantom to scan, plan, treat, and verify cumulative uncertainties within 0.1 mm. Learn the advantages of using Lucy for true end-to-end stereotactic QA at our upcoming webinar.
    Register
    Register
    Lucy pointer

    Jan 13th, 2022 / End-to-End Stereotactic QA

    Stereotactic QA using the Lucy 3D QA Phantom makes scanning, planning, and treating faster and easier. Unrivaled 0.1mm accuracy, the Lucy Phantom minimizes errors and is the most precise, practical SRS tool on the market.
    Register
    Register
    Lucy lockplate

    Oct 7th, 2021 / Specialized Stereotactic QA

    Exceed the strict demands of Stereotactic QA with phantoms that combine accuracy and precision. Use the Lucy 3D QA Phantom to scan, plan, treat, and verify with an unrivaled 0.1mm accuracy. Use the Stereotactic Dose Verification Phantom (SDVP) for SBRT lung and/or CyberKnife QA.
    Register
    Register
    Webinar Lucy 061021

    Jun 10th, 2021 / Precise SRS Within 0.1mm Tolerance

    Precisely validate the complete Stereotactic QA process from end-to-end using the LUCY 3D QA Phantom. Learn how this most precise phantom can elevate your stereotactic QA.
    Register
    Register
    010721 Webinar Graphic Web

    Jan 7th, 2021 / End-to-End Stereotactic QA

    Validate the complete Stereotactic QA chain with precise scanning, planning, and treating. When precision and accuracy matter most – use the Lucy 3D QA Phantom.
    Register

Tech Notes

Please sign in or register to the customer care portal to view tech notes.

Have Questions About the LUCY™ 3D QA Phantom?

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Request Pricing for Complete Stereotactic Solution

Uncompromising tolerances for unwavering trust. Receive more information about Stereotactic QA Solutions.

Learn more about Standard Imaging Stereotactic

Join our Mailing List